Building Types
Accepted Building Types
-
- Single Family Homes
- Duplexes
- Triplexes
Rejected Building Types
-
-
Carports
- Condos
- Manufactures homes (ok for Ground Mounted systems)
-
Main Service Panel Types
Automatic MPU Types
-
- Hot Busses or Split Busses
- Unless we get confirmation that the AHJ will grandfather an existing
- If there is damage to the Main Panel
- Backfeed Capacity is reached
- If the Main Panel is one of the following panel types
- Federal Pacific
- Bulldog
- Pushmatic
- Stabloc
- Zinsco
- Challenger
- Hot Busses or Split Busses
Rejected MPU Types
-
- Underground Panels in one of the following utilities
- PGE
- SDGE
- Financed SDGE MPUs
- Customer Payment Deals and Sunrun deals are okay
- Underground Panels in one of the following utilities
Roof Types
Accepted Roof Types
-
-
Comp Shingle
- With solid sheathing and no more than 2 layers
- Must be in good condition with no balding, fiberglass showing, or cracked or missing shingles
-
-
Flat Roof (BUR)
- a.k.a. “torch down”, “hot tar” or “mod bit” rolled comp
- Must be in good condition, with no balding or fiberglass showing, or buckling/wavy areas,
- No open seams or separating along the edges or flashings.
-
TPO or Membrane
- TPO or any other single-ply membrane roof
-
Tar and Gravel
- Must be in good condition
- No balding, cracking, or separating along the edges from the metal flashing
-
Spray Polyurethane (SPF)
- Must be in good condition
- No bubbles or areas where the coating is delaminating showing the yellow foam beneath
-
Concrete Tile
- All profiles, S tile, flat tile, and M/W tile must be standard weight (over 9 lbs. per tile for
normal-sized tiles that have 88 tiles per square) – underlayment must pass the stress test – cannot be dried out and brittle
- All profiles, S tile, flat tile, and M/W tile must be standard weight (over 9 lbs. per tile for
-
Standing Seam Metal
- Seam must be tall enough and strong enough for the mounting clamp to grip the seam.
- Hexagonal/trapezoidal must be able to clamp to raised corrugation.
- Not an option in high-wind areas.
-
Comp Shingle
Re-roof Required Roof Types
-
-
Clay Tile
- Any type of clay tile must have a PV area (full roof plane) reroofed with “clay tile –comp out”
-
Lightweight concrete
- Under 9 lbs per tile, any type of clay tile must have a PV area (full roof plane)reroofed with “clay tile – comp out”
-
Metal Tile
- a.k.a. “Decra” or “Calpac”
- Must reroof to a supported roof type – minimum PV area only (most economical option would be comp shingle)
-
Wood Shake / Shingle
- Must reroof to a supported roof type – min PV area only (most economical option would be comp shingle)
-
Corrugated Metal
-
- Any other profile besides those listed above in Qualified roof types must reroof with standing seam or hexagonal metal
-
-
Custom Special-Order Tile
- Must reroof to a supported roof type – min PV area only (most economical option would be comp shingle)
-
Cal-shake Cement Fiber
- Must reroof to a supported roof type – minimum PV area only (most
economical option would be comp shingle)
- Must reroof to a supported roof type – minimum PV area only (most
-
Clay Tile
Rejected Roof Types
-
- Any roof over 45 degrees will be rejected regardless of roof type